Full Opening Check Valve, full bore with a smooth flow path, automatically operated by line pressure. A check valve for backflow prevention where low resistance is critical. Used in petroleum, chemical, pharmaceutical, fertilizer, power, and cryogenic pipelines. Full bore means no flow restriction, and a smooth path means no turbulence. Pressure drop stays low, pumps use less energy, and your system runs efficiently around the clock.

Send your specs and we will confirm size and rating for your line.

Share This Product

Specification

Size: 2″-36″
Pressure: 150LB-2500LB
Body Material: WCB, WC6, WC9, CF8, CF8M, CF3, CF3M, CN7M, LC1, LC2, LC3, LCB, LCC, Monel, 20# Alloys, 4A, 5A, C95800, C95500, A105, F304, F304L, F316, F316L, LF1, LF2, LF3, LF9, F51, F53, F11, F22, etc.
Seal Material: STELLITE, 13Cr, SS304, SS316, etc.
Connection Type: Flanged, Butt Welded, Socket Welded, NPT
Face to Face Dimension: ASME B16.10
Flange End Dimension: ASME B16.5
Butt Welded Dimension: ASME B16.25
Design and Manufacture: BS1868,API 6D
Test Standard: API 598,API 6FA, ISO 15848-1-2

 

Features

Smooth flow path, small fluid resistance with fully open flow channel

Fully open with API6D standard structure, and flow channel is smooth.

Available with single plate disc, swing type

With lifting eye bolts on size 4” and larger

Renewable seat/integral seat, suitable for horizontal installation

Suitable for petroleum, chemical, pharmaceutical, chemical fertilizer, power industry, low temperature, and other conditions of the pipeline

Frequently Asked Questions

What is a check valve used for

A check valve is a type of valve that allows fluid to flow in only one direction. It is commonly used to prevent backflow in piping systems where the reversal of flow could cause damage or contamination. Check valves are often used in water and wastewater treatment plants, oil and gas pipelines, and in many other industrial applications. api 6d ball valve

Can a check valve be installed vertically

Yes, a check valve can be installed vertically. Check valves are designed to work in various orientations, including vertical, horizontal, and angled positions. The important factor to consider when installing a check valve vertically is to ensure that the flow direction aligns with the arrow or indicator on the valve body. This ensures that the valve functions properly and prevents backflow in the desired direction. Additionally, it is important to follow the manufacturer’s guidelines and recommendations for proper installation and orientation of the check valve to ensure optimal performance and longevity. forged ball valve

What is the check valve

A check valve, also known as a non-return valve or one-way valve, is a type of valve that allows fluid or gas to flow in one direction while preventing backflow in the opposite direction. It consists of a valve body with an inlet and outlet, and a movable disc or flap that opens and closes to control the flow of fluid or gas.

Check valves are commonly used in a variety of applications, including plumbing systems, industrial processes, and water and wastewater treatment plants. They are designed to prevent backflow, which can cause damage to equipment, contamination of fluids, or other safety hazards. carbon steel gate valves

There are several types of check valves, including swing check valves, ball check valves, and diaphragm check valves. Each type has its own advantages and disadvantages, and the choice of valve depends on the specific application and requirements.

Overall, check valves are an important component in many fluid and gas systems, providing reliable and effective backflow prevention to ensure safe and efficient operation. high temperature gate valves

Can a check valve be mounted horizontally

Yes, a check valve can be mounted horizontally. However, the specific orientation of the valve will depend on the type of check valve and the application.

In general, swing check valves and ball check valves can be mounted horizontally without any issues. However, diaphragm check valves may need to be mounted vertically to ensure proper function.

It is important to follow the manufacturer’s instructions and guidelines when installing a check valve, including the recommended orientation and mounting position. Improper installation can lead to reduced performance, increased wear and tear, and potential safety hazards, low temperature ball valves.

Overall, while a check valve can be mounted horizontally, it is important to ensure that the specific valve and application are compatible with this orientation to ensure reliable and safe operation.

What is a full flow check valve

A full flow check valve is a type of check valve that is designed to provide unobstructed flow through the valve when it is open. Unlike some other types of check valves, which can cause a significant pressure drop or flow restriction when they are in the open position, a full flow check valve allows fluid to flow through the valve with minimal resistance.

Full flow check valves are commonly used in applications where low pressure drop and high flow rates are important, such as in large pipelines or high-volume pumping systems. They are often used in conjunction with other flow control devices, such as flow meters or pressure regulators, to ensure that the system operates efficiently and reliably, api602 forged gate valve.

There are several different types of full flow check valves available, including ball check valves, swing check valves, and wafer check valves. The specific type of valve that is used will depend on the application and the specific requirements of the system.

Table of Contents

Inquiry Now

Any questions? Send us message now! We’ll serve your request with a whole team after receiving your message.

Whats APP @ MAIL